SAAB WIS ONLINE

DTC P0032 HO2S HEATER CONTROL CIRCUIT HIGH (BANK 1 SENSOR 1)

DTC P0032 HO2S HEATER CONTROL CIRCUIT HIGH (BANK 1 SENSOR 1)

OUTLINE OF DIAGNOSIS

Detect the open or short circuit of front oxygen (A/F) sensor heater. Diagnosis is performed using front oxygen (A/F) sensor IC, and communication is established between front oxygen (A/F) sensor IC and main IC. Front oxygen (A/F) sensor IC judges NG when the data of voltage and current is abnormal with heater turned on or off.

COMPONENT DESCRIPTION


(1)

Protection tube

(2)

Gasket

(3)

Sensor housing

(4)

Ceramic heater



ENABLE CONDITION

Secondary Parameters Enable Conditions
None



GENERAL DRIVING CYCLE

Always perform diagnosis continuously.

DIAGNOSTIC METHOD

Front oxygen (A/F) sensor IC judges NG when the continuous time until completing one of the malfunction criteria below becomes more than the time needed for diagnosis (4.5 seconds). Front oxygen (A/F) sensor IC judges OK and clear NG when any of the malfunction criteria below are not completed.

Judgment Value

Malfunction Criteria Threshold Value
Heater circuit

OFF


Voltage


> 5 V


Current


> 1.5 A


Heater current


≥ 23 A



Time Needed for Diagnosis: 4.5 seconds

Malfunction Indicator Light Illumination: Illuminates as soon as the malfunction occurs.

DTC CLEAR CONDITION


When the OK idling cycle was completed 40 times in a row

When “Clear Memory” was performed


MALFUNCTION INDICATOR LIGHT CLEAR CONDITION


When the OK driving cycle was completed 3 times in a row

When “Clear Memory” was performed


FAIL SAFE


Front oxygen (A/F) sensor main learning correction: Not allowed to calculate

Correction when re-starting at high temperature: Normally minimum value 0.3 → 0

GST communication: Mode$01 “Failure” is indicated in A/F feedback control condition

Purge control: Not allowed to purge


ECM OPERATING AT DTC SETTING

Memorize the freeze frame data. (For test mode $02)