DTC P0112 INTAKE AIR TEMPERATURE CIRCUIT LOW INPUT
|
DTC P0112 INTAKE AIR TEMPERATURE CIRCUIT
LOW INPUT
|
Detect the open or short circuit of intake
air temperature sensor. Judge NG when out of the standard value.
(1)
|
Air flow
sensor
|
(A)
|
Air
|
(2)
|
Intake
air temperature sensor
|
|
|
(3)
|
Resistance
(Ω)
|
|
|
(4)
|
Intake
air temperature °C (°F)
|
|
|
Secondary
Parameters
|
Enable
Conditions
|
None
|
|
Always perform the diagnosis continuously.
Abnormality Judgment
Judge NG when the continuous time of completing
the malfunction criteria below becomes more than 0.5 seconds.
Judgment
Value
Malfunction
Criteria
|
Threshold
Value
|
Output
voltage
|
< 0.23
V
|
Ignition
switch
|
ON
|
Time Needed for Diagnosis:
0.5
seconds
Malfunction Indicator
Light Illumination:
Illuminates as soon as the malfunction
occurs.
Normality Judgment
Judge OK and clear the NG when the malfunction
criteria below are completed.
Judgment
Value
Malfunction
Criteria
|
Threshold
Value
|
Output
voltage
|
≥ 0.23
V
|
Ignition
switch
|
ON
|
•
|
When the OK idling cycle was completed 40 times
in a row
|
•
|
When “Clear Memory” was
performed
|
MALFUNCTION
INDICATOR LIGHT CLEAR CONDITION
|
•
|
When the OK driving cycle was completed 3 times
in a row
|
•
|
When “Clear Memory” was
performed
|
Intake air temperature sensor process: Intake
air temperature is fixed at 20°C (68°F).
ECM OPERATING
AT DTC SETTING
|
Memorize the freeze frame data. (For test
mode $02)