DTC P0244 TURBO/SUPER CHARGER WASTEGATE SOLENOID “A” RANGE/PERFORMANCE
|
DTC P0244 TURBO/SUPER CHARGER WASTEGATE
SOLENOID “A” RANGE/PERFORMANCE
|
Detect the malfunction of wastegate control
solenoid valve function. Judge NG when becoming high wastegate pressure.
Secondary
Parameters
|
Enable
Conditions
|
None
|
|
Always perform the diagnosis continuously.
Judge NG when the continuous time of completing
the malfunction criteria below becomes more than 2 second. Judge
OK and clear the NG when the malfunction criteria below are not
completed.
Judgment
Value
Malfunction
Criteria
|
Threshold
Value
|
Intake
manifold pressure
|
Refer to
table 1
|
Table
1
Atmospheric
pressure
kpa (mmHg, inHg)
|
67.2 (504, 19.8)
|
75.7 (568, 22.4)
|
84.3 (632, 24.9)
|
92.8 (696, 27.4)
|
101.3 (760, 29.9)
|
Pressure
kpa (mmHg, inHg)
|
157.9 (1,184,
46.6)
|
178.4 (1,338,
52.7)
|
199.1 (1,493,
58.8)
|
212.8 (1,596,
62.8)
|
219.6 (1,647,
64.8)
|
Time Needed for Diagnosis:
2
seconds
Malfunction Indicator
Light Illumination:
Illuminates as soon as the malfunction
occurs.
•
|
When the OK idling cycle was completed 40 times
in a row
|
•
|
When “Clear Memory” was
performed
|
MALFUNCTION
INDICATOR LIGHT CLEAR CONDITION
|
•
|
When the OK driving cycle was completed 3 times
in a row
|
•
|
When “Clear Memory” was
performed
|
None
ECM OPERATING
AT DTC SETTING
|
Memorize the freeze frame data. (For test