DTC P0716 INPUT/TURBINE SPEED SENSOR CIRCUIT RANGE/PERFORMANCE
|
DTC P0716 INPUT/TURBINE SPEED SENSOR
CIRCUIT RANGE/PERFORMANCE
|
Judge NG when the turbine speed signal is
not transmitted for some reasons.
Torque converter turbine speed sensor (output
shaft speed sensor) is installed to the outside of transmission case.
This sensor detects the turbine speed of torque converter by the
peripheral speed of high clutch drum connected to input shaft. And
then it transmits the sine wave signal (32 pulses per rev.) to TCM.
TCM calculates the ratio of the input shaft speed to vehicle speed,
and then makes a judgment whether to shift or not.
Secondary
Parameters
|
Enable
Conditions
|
Engine
speed
|
≥ 1,500
rpm
|
Vehicle
speed
|
≥ 40
km/h (25 MPH)
|
Range switch
|
“D”, “3”, “2” or “1”
|
Always perform the diagnosis continuously.
Perform the diagnosis when the conditions
below were continued for 2 seconds.
1.
|
Except “P”, “N”, “R” ranges
and inhibitor switch is normal.
|
2.
|
Engine speed is more than 3,000 rpm.
|
3.
|
Vehicle speed is 30 km/h (19
MPH) and vehicle speed sensor is normal.
|
4.
|
Turbine speed is more than 600 rpm.
|
Judgment
Value
Malfunction
Criteria
|
Threshold
Value
|
Output
from turbine shaft speed
|
< 600
rpm
|
Time Needed for Diagnosis:
2
seconds
Malfunction Indicator
Light Illumination:
Illuminates when malfunction occurs in
2 continuous driving cycles.
•
|
When the OK idling cycle was completed 40 times
in a row
|
•
|
When “Clear Memory” was
performed
|
MALFUNCTION
INDICATOR LIGHT CLEAR CONDITION
|
•
|
When the OK driving cycle was completed 3 times
in a row
|
•
|
When “Clear Memory” was
performed
|
None
ECM OPERATION
AT DTC SETTING
|
Memorize the freeze frame data. (For test