DTC P0464 FUEL LEVEL SENSOR CIRCUIT INTERMITTENT
|
DTC P0464 FUEL LEVEL SENSOR CIRCUIT INTERMITTENT
|
Detect the malfunction of unstable output
from fuel level sensor caused by noise.
Judge NG when the max. value and cumulative
value of output voltage variation of fuel level sensor is larger than
the threshold value.
Secondary
Parameters
|
Enable
Conditions
|
Engine
speed
|
≥ 500
rpm
|
After
engine starting
|
1
second or more
|
Ignition
switch
|
ON
|
Battery
voltage
|
> 10.9
V
|
Idle
switch
|
ON
|
Fuel
level
|
9.0 ←→ 51 litres (10.1 ←→ 50.7
US gal, 8.4 ←→ 42.2 Imp gal)
|
Vehicle
speed = 0 km/h (0 MPH)
|
10 seconds
or more
|
•
|
Perform the diagnosis continuously in idling
condition.
|
•
|
Pay attention to the fuel level.
|
Calculate the Max. value (delflmax) and cumulative
value (sumfl) of output voltage variation of fuel level sensor during
12.2 seconds. Judge it normal when both max. and cumulative values
are not over the threshold value. Otherwise, when either of them
is over the threshold value, count the diagnosis counter up. And
judge NG if the counter indicated 4 counts.
Abnormality Judgment
Judge NG when the malfunction criteria below
are completed.
Judgment
Value
Malfunction
Criteria
|
Threshold
Value
|
Integrated
times of the condition reaching follows,
DELFLMAX ≥ 0.2 ←→ 0.26 V or SUMFL ≥ 16
V
where,
DELFLMAX is Max. deviation of sensor output during 12.2 seconds.
SUMFL is integrated value of sensor output deviation during
12.2 seconds.
|
≥ 4
times
|
Do not count the diagnosis counter up when
the following conditions are completed during 12.3 seconds.
Max − Min
of tank pressure during 12.2 seconds
|
≥ 0.05
kPa (0.375 mmHg, 0.02 inHg)
|
Max − Min
of battery voltage during 12.2 seconds
|
≥ 0.465
V
|
Time Needed for Diagnosis:
12.2
seconds × 4 times
Malfunction Indicator
Light Illumination:
Illuminates when malfunction occurs in
2 continuous driving cycles.
Normality Judgment
Judge OK and clear the NG when the malfunction
criteria below are completed.
Judgment
Value
Malfunction
Criteria
|
Threshold
Value
|
DELFLMAX
|
< 0.2 ←→ 0.26
V
|
SUMFL
Where, DELFLMAX is Max. deviation of sensor output during
12.2 seconds. SUMFL is integrated value of sensor output deviation
during 12.2 seconds.
|
< 16
V
|
•
|
When the OK idling cycle was completed 40 times
in a row
|
•
|
When “Clear Memory” was
performed
|
MALFUNCTION
INDICATOR LIGHT CLEAR CONDITION
|
•
|
When the OK driving cycle was completed 3 times
in a row
|
•
|
When “Clear Memory” was
performed
|
None
ECM OPERATION
AT DTC SETTING
|
Memorize the freeze frame data. (For test
mode $02)