OPERATION
OPERATION |
Vehicle Diagnostic Interface (NORMAL MODE) |
On «Main Menu» display screen, select the {2. Each System Check}.
On «System Selection Menu» display screen, select the {Engine Control System}.
Select the {OK} after the information of engine type is displayed.
On «Engine Diagnosis» display screen, select the {Clear Memory}.
After the ‘Done’ is shown on display screen, turn the ignition switch to OFF, and then turn the Vehicle Diagnostic Interface to OFF.
Note | ||
For detailed operation procedure, refer to Vehicle Diagnostic Interface OPERATION MANUAL. |
Vehicle Diagnostic Interface (OBD MODE) |
On «Main Menu» display screen, select the {2. Each System Check}.
On «System Selection Menu» display screen, select the {Engine Control System}.
Select the {OK} after the information of engine type is displayed.
On «Engine Diagnosis» display screen, select the {OBD System}.
On «OBD Menu» display screen, select the {4. Diagnosis Code(s) Cleared}.
After the ‘Clear Diagnostic Code?’ is shown on the display screen, select the {OK}.
Turn the Vehicle Diagnostic Interface and ignition switch to OFF.
Note | ||
For detailed operation procedure, refer to Vehicle Diagnostic Interface OPERATION MANUAL. |
OBD-II GENERAL SCAN TOOL |
For clear memory procedures using the OBD-II general scan tool, refer to OBD-II General Scan Tool Instruction Manual.
After the memory has been cleared, the idle air control solenoid valve must be initialized. To do this, turn the ignition switch to ON position. Wait 3 seconds before starting the engine.