ELECTRICAL SPECIFICATION
ELECTRICAL SPECIFICATION |
Contents
|
To Connector No.
|
Terminal No.
|
Input/Output
signal
|
Measured
value and measuring conditions
|
|||
Battery
power supply
|
B280
|
2
|
9 — 16
V
|
Ignition
power supply
|
B281
|
19
|
10 — 15
V when ignition switch is at ON or START.
|
Ignition
power supply
|
B281
|
10
|
10 — 15
V when ignition switch is at ACC.
|
Inhibitor
Switch (“P” range)
|
B281
|
5
|
0
V when select lever is in “P” range.
9 — 16 V when select lever is in other ranges than “P” range. |
Stop
light switch
|
B281
|
9
|
9 — 16
V when stop light switch is ON.
0 V when stop light switch is OFF. |
“P” range
switch
|
B281
|
6
|
0
V when select lever is in “P” range.
9 — 16 V when select lever is in other ranges than “P” range. |
Shift
lock solenoid signal
|
B280
|
9
|
8.5 — 16
V when shift lock is released.
0 V when shift lock is operating. |
Key
warning switch signal
|
B281
|
20
|
9 — 16
V when key is inserted.
0 V when key is removed. |
Key
lock solenoid signal
|
B280
|
3
|
7.5 — 16
V when turning ignition switch to ON, select lever is in “P” range
and brake switch is ON.
0 V at other conditions than above. |
Ground
|
B280
|
4
|
—
|
Ground
|
B280
|
13
|
—
|