SAAB WIS ONLINE

ELECTRICAL SPECIFICATION

ELECTRICAL SPECIFICATION


Contents

To Connector No.

Terminal No.

Input/Output signal

Measured value and measuring conditions

Battery power supply

B280

2

9 — 16 V

Ignition power supply

B281

19

10 — 15 V when ignition switch is at ON or START.

Ignition power supply

B281

10

10 — 15 V when ignition switch is at ACC.

Inhibitor Switch (“P” range)

B281

5

0 V when select lever is in “P” range.

9 — 16 V when select lever is in other ranges than “P” range.

Stop light switch

B281

9

9 — 16 V when stop light switch is ON.

0 V when stop light switch is OFF.

“P” range switch

B281

6

0 V when select lever is in “P” range.

9 — 16 V when select lever is in other ranges than “P” range.

Shift lock solenoid signal

B280

9

8.5 — 16 V when shift lock is released.

0 V when shift lock is operating.

Key warning switch signal

B281

20

9 — 16 V when key is inserted.

0 V when key is removed.

Key lock solenoid signal

B280

3

7.5 — 16 V when turning ignition switch to ON, select lever is in “P” range and brake switch is ON.

0 V at other conditions than above.

Ground

B280

4



Ground

B280

13