INSPECTION
INSPECTION |
Switch
position
|
Terminal
No.
|
Standard
|
OFF
|
3 and 5
|
More
than 1 MΩ
|
ON
|
Less
than 1 Ω
|
FRONT FOG LIGHT RELAY |
Measure the front fog light relay resistance between terminals when connecting terminal No. 4 to battery positive terminal and terminal No. 3 to battery ground terminal.

Current
|
Terminal
No.
|
Standard
|
Flow
|
1 and 2
|
Less
than 1 Ω
|
No
flow
|
More
than 1 MΩ
|