SAAB WIS ONLINE

INSPECTION

INSPECTION


Inspect the continuity between each connector terminal.


Switch position Terminal No. Standard
FRONT

OFF

7 and 16

Less than 1 Ω

INT

7 and 16

Less than 1 Ω

LO

7 and 17

Less than 1 Ω

HI

8 and 17

Less than 1 Ω

Washer ON

2 and 11

Less than 1 Ω

REAR

Washer ON



Less than 1 Ω

OFF



More than 1 MΩ

ON

2 and 10

Less than 1 Ω

Washer ON



Less than 1 Ω



If continuity is not as specified, replace the switch.



Intermittent operation inspection


Turn the wiper switch to INT.

Adjust the intermittent control switch to MAX.

Apply battery voltage to switch terminals 16 and 2.

Inspect the voltage of combination switch terminals.

Terminals

No. 7 — No. 2:


(A)

Switch position

(E)

Non variable type

(I)

16±6 sec.

(B)

Voltage

(F)

12 V

(J)

3.3±1 sec.

(C)

MIN.

(G)

0 V

(D)

MAX.

(H)

1.6±1 sec.



If operation is not as specified, replace the switch.