INSPECTION
INSPECTION |
Disconnect the connector from wiper control relay.
Connect the positive (+) lead from the battery to terminal 8 and the negative (−) lead to terminal 6. Connect the positive (+) lead from the voltmeter to terminal 3 and the negative (−) lead to ground.
(1)
|
Switch
position
|
(2)
|
Voltage
|
(3)
|
9±2
sec.
|
If operation is not as specified, replace the switch.