INSPECTION
INSPECTION |
If any damage, deformation, wear, swelling, rust, and other faults are found on the primary piston assembly, secondary piston assembly, supply the valve stopper, or gasket, replace the faulty part.
Note | ||
• |
The primary and secondary pistons
must be replaced as complete assemblies.
|
|
• |
The service limit of clearance between each piston and
the master cylinder inner dia. is 0.11 mm (0.0043 in).
|