PROCEDURE
PROCEDURE |
Important | ||
• |
During operation, be sure to
wear safety goggles and protective gloves.
|
|
• |
Connect the refrigerant recovery system with the manifold
gauge set to discharge the refrigerant from the A/C system
and reuse it.
|
|
• |
When reusing the discharged refrigerant, keep service
cans on hand. Because the discharge rate with the recovery system
is approx. 90%, service cans are necessary to charge the refrigerant.
|
|
• |
Follow the detailed operation procedure described in
the operation manual attached to the refrigerant recovery system.
|
|
Perform the compressor oil return operation.
Stop the engine.
Make sure the valves on low-/high-pressure sides of manifold gauge set are fully closed.
(A)
|
Low-pressure
gauge (Compound pressure gauge)
|
(B)
|
High-pressure
gauge
|
(C)
|
Close
|
Install the low-/high-pressure hoses to the service ports on the low-/high-pressure sides of the vehicle respectively.
(A)
|
Low-pressure
gauge (Compound pressure gauge)
|
(B)
|
High-pressure
gauge
|
(C)
|
Close
|
(D)
|
Low-pressure
side service port
|
(E)
|
High-pressure
side service port
|
Connect the center hose to the refrigerant recovery system.
Follow the operation manual to activate the refrigerant recovery system.