INSPECTION
INSPECTION |
KEYLESS TRANSMITTER BATTERY |
Measure the voltage between battery (+) terminal and (−) terminal.
Note | ||
• |
Battery discharge occurs during measurement. Complete
the measurement within 5 seconds.
|
(A)
|
Resistance
47 Ω
|
Tester connection
|
Standard
|
|
(+)
|
(−)
|
|
Battery
(+) terminal
|
Battery
(−) terminal
|
2.5 — 3.0
V
|
If NG, replace the battery. (Use CR1620 or equivalent.)