SAAB WIS ONLINE

INSPECTION

INSPECTION

KEYLESS TRANSMITTER BATTERY

Measure the voltage between battery (+) terminal and (−) terminal.

Note
Battery discharge occurs during measurement. Complete the measurement within 5 seconds.



(A)

Resistance 47 Ω



Tester connection

Standard

(+)

(−)

Battery (+) terminal

Battery (−) terminal

2.5 — 3.0 V



If NG, replace the battery. (Use CR1620 or equivalent.)