Measure values, control module connections, SID

Measure values, control module connections, SID




Scope

Below the headings, values and directions can be found for measuring voltage levels of the SID unit.

Keep in mind


Note the measuring conditions, use common sense when considering the measurement results.

The values presented are with ignition ON if nothing else is stated.

First check that the control module is supplied with power and that it is grounded.

Then check all the inputs and signals from other systems.

Finally, check the control module outputs. Remember that the measured values will not indicate if the switch device is functional.

If any measured value is incorrect, use the wiring diagram to diagnose which leads, connections or components that should be checked further.

Given values refer to calibrated Fluke 88/97.

The measured values %(+) and ms(+) shows the pulse of the signal respective pulse length. Test instrument with pulse quotient respective pulse width measuring capacity must be used. The sign (+) indicates positive trigger pulse, TRIG+.




> = greater than; < = less than; ~ = alternating current

A pin without further comments does not have a pin connection. (LP: LOGIC PROBE P= select pulse; p= visible pulses)


Pin no.

Lead colour

Component/function

In/out

Measuring condition

Measure between

Value

See

20

BU/RD

Parking heater/Auxiliary heater

Out

Activated

20-1

0 V











Not activated

20-1

B+