Cleaning the mass air flow sensor
|
Cleaning the mass air flow sensor
|
1.
|
Put the ignition in position OFF.
|
2.
|
Mark the position of the sensor and unplug the connector
|
3.
|
Remove the sensor. Use a Torx bit T20 with centre hole (safety bit). Place the sensor on a rag to soak up any spills during cleaning.
|
4.
|
Spray the top and bottom of the sensor with Electronics cleaner 30 04 223. Allow the liquid to work for approx. 1 minute. Exercise caution; the sensor components should not come into contact with tools or other devices.
|
5.
|
Carefully blow clean the sensor internally and externally with compressed air. Keep a distance of at least 30 cm.
|
6.
|
Repeat this treatment twice.
|
7.
|
Lubricate the sensor O-ring sparingly with petroleum jelly to facilitate fitting.
|
8.
|
Fit the sensor according to the marking. The sensor is calibrated in this position and it must therefore be refitted in its original position.
|
9.
|