Trionic control module
| Trionic control module |
| Important | ||
|
If a winding in the APC valve is short-circuited, the control module is probably also damaged and any new valves being fitted will be destroyed. Consequently, in case of a short circuit, the valve and the control module must both be changed at the same time. |
||
| 1. |
Turn off the ignition.
|
|
| 2. |
Remove the glove box.
|
|
| 3. |
Fold back the carpet and remove the central locking system relay.
|
|
| 4. |
Unplug the connector and remove the control module.
|
|
| To fit |
| 1. |
Fit the control module.
|
|
| 2. |
Plug in the connector.
|
|
| 3. |
Fit the central locking system relay.
|
|
| 4. |
Refit the glove box.
|
|
| 5. |
Reset the immobilizer as follows:
|
|
| • |
Connect Tech2 and turn the ignition ON.
|
| • |
Select Body and TWICE.
|
| • |
Select Immobilizer. After roughly 10 seconds, the immobilizer will have been programmed.
|