A/C engagement
A/C engagement |
A/C request |
A number of conditions must be fulfilled in order for the A/C relay to be grounded and for the A/C compressor clutch to begin to draw power.
For control panel with A/C, the function is activated manually. In order for an A/C request to be completed, the fan must be in position 1-4 and the A/C button in the ON position.
For ACC, the A/C request is automatic when the ACC-panel is ON (that is, OFF is not pushed in), ECON is not selected, the engine is running and the outside temperature exceeds +1˚C.
The engine management system compensates the engine for the extra load of the compressor.
A/C engagement |
1. |
A/C request comes from the control panel with A/C or ACC.
For control panel with A/C, the signal arrives on a direct lead, and for ACC the information goes on the bus to DICE. |
2. |
The pressure in the condenser must be lower than 27 bar and higher than 2 bar. The pressure sensor senses the pressure in the condenser and sends the information to DICE.
|
3. |
The temperature in the evaporator must exceed +4˚C. DICE receives the information from the anti-freeze sensor.
|
4. |
The engine temperature must be lower than +126˚C (petrol engine) and +118˚C (diesel engine). DICE receives the information from the engine management system on the bus via MIU.
|
5. |
The conditions for A/C request are fulfilled and the engine management system grounds the A/C relay. When the relay is grounded, power is supplied via the compressor temperature monitor. If the temperature monitor has been activated, it is reset automatically.
|
Important | ||
If a trouble code is generated for any of the sensors for above values, the conditions for engagement of the A/C are not fulfilled. |
||