SAAB WIS ONLINE

Checking injector flow capacity

Checking injector flow capacity

To remove



1. Remove the fuel rail with injectors as described in steps 1-6 in the section “injectors, see

2. Start the fuel pump by connecting jumper lead 83 93 886 between fuses 4 and 32. Make sure the injectors are not leaking.

3. Connect test hose 83 94 405 to the injector being tested and place the other end into a measuring glass. Connect the valve to battery voltage using cable 86 11 410 and jumper cable 86 11 345 . Activate the valve for exactly 30s and then check that the amount of fuel in the measuring glass is 126± 5 ml. The maximum difference allowed between injectors is 18 ml.


4. Change any defective injectors.


Warning

Provide adequate ventilation!


To fit


1. Fit the fuel rail and injectors. Make sure the correct connector is plugged to the relevant injector.


Checking fuel pressure



See Service Manual "2:3 Fuel System" for checking the fuel pressure/fuel pressure regulator.