Resetting triggered limp-home solenoid
|
Resetting triggered limp-home solenoid
|
1.
|
Remove the engine cover.
|
2.
|
Put the ignition in ON position.
|
3.
|
Contact Trionic with the diagnostic tool and clear diagnostic trouble codes.
|
4.
|
Put the ignition in the OFF position and wait 10 s.
|
5.
|
Carefully push the end of the spring towards the throttle body.
|
6.
|
Rotate the black tooth disc anti-clockwise with a screwdriver. A click will be heard in its end position.
|
7.
|
Rotate the pedal arm clockwise.
|
8.
|
Make sure the throttle arm does not follow with the pedal arm when it is rotated.
|