B1347

Read the instructions below then start the fault diagnostic procedure.

Symptom: Experienced temperature in cabin is too high or too low compared to selected temperature.

B1347


Mixed-air sensor. Shorted to ground.

Mixed-air sensor. Open circuit/shorted to B+


Fault symptom

Experienced temperature in cabin is too high or too low compared to selected temperature.

Conditions

The following conditions apply:


• Open circuit or short-circuit to B+.

• Shorted to ground on pin.

• Measured every 440 ms and 5 measurements in a row are required to generate a diagnostic trouble code.

• The diagnostic trouble code is erased after ignition has been switched on 20 times if the problem conditions have not been fulfilled.

• When the diagnostic trouble code is generated, the control module uses the replacement value which is based on the air-mixing damper relative opening multiplied by the coolant temperature.