SAAB WIS ONLINE

B2375

Read the instructions below then start the fault diagnostic procedure.

Symptom: Experienced temperature in cabin is too high or low when compared to set temperature.

B2375


Heater box solenoid. Shorted to B+

Heater box solenoid. Open circuit/shorted to ground


Fault symptom

Experienced temperature in cabin is too high or low when compared to set temperature.

Conditions

The following conditions apply:


• Shorted to B+ is indicated when the output for the heater box solenoid is activated and the voltage on pin 24 exceeds 6 V.

• Measured every 440 ms and 5 measurements in a row are required to generate a diagnostic trouble code.

• The diagnostic trouble code is erased after ignition has been switched on 20 times if the problem conditions have not been fulfilled.

• The output is closed when the diagnostic trouble code is generated.