Read the instructions below then start the fault diagnostic procedure.

Symptom: Experienced temperature in cabin is too high or low when compared to set temperature.

B2495 , B2496


Stepping motor air-mixing, loose damper. Note: May be generated if not calibrated

Stepping motor air-mixing, damper jammed. Note: May be generated if not calibrated





Fault symptom

Experienced temperature in cabin is too high or low when compared to set temperature.

Conditions

The following conditions apply:


• When the stepping motor is run by the control module towards an end position and if the stepping motor continues more than 20% past the expected end position, the diagnostic trouble code for loose damper is generated.

• When the stepping motor works in the range 10-90 % of the damper operating range (which is 0-100 %), the control module senses if the power consumption exceeds a certain value, and generates the diagnostic trouble code for jammed damper.

• The diagnostic trouble codes may be generated if the control module has not been calibrated.

• Continuous monitoring and during calibration.