Air recirculation motor
| Air recirculation motor |
| 1. |
Remove the glove box. See 8:2 Interior equipment.
|
|
| 2. |
Remove the air duct.
|
|
| 3. |
Unplug the electric connector.
|
|
| 4. |
Remove the recirculation motor from the climate control unit housing by unhooking the locking tongues.
|
|
| 5. |
Disconnect the motor shaft from the wire. The wire is angled at the end and locked by a clip. Use pliers to turn the clip so that the wire can be removed.
|
|
| 6. |
Lift out the recirculation motor.
|
|
| Fitting |
| 1. |
Connect the motor shaft to the wire. The wire is angled at the end and must be locked across a clip. Use a screwdriver to turn the clip so that the wire can be locked.
|
|
| 2. |
Press the motor into the climate control unit housing.
|
|
| 3. |
Plug in the connector.
|
|
| 4. |
Refit the air duct.
|
|
| 5. |
Refit the glove box. See 8:2 Interior equipment.
|
|