Measure values, control module connections, SID
|
Measure values, control module connections, SID
|
Below the headings, values and directions can be found for measuring voltage levels of the SID unit.
•
|
Note the measuring conditions, use common sense when considering the measurement results.
|
•
|
The values presented are with ignition ON if nothing else is stated.
|
•
|
First check that the control module is supplied with power and that it is grounded.
|
•
|
Then check all the inputs and signals from other systems.
|
•
|
Finally, check the control module outputs. Remember that the measured values will not indicate if the switch device is functional.
|
•
|
If any measured value is incorrect, use the wiring diagram to diagnose which leads, connections or components that should be checked further.
|
•
|
Given values refer to calibrated Fluke 88/97.
|
•
|
The measured values %(+) and ms(+) shows the pulse of the signal respective pulse length. Test instrument with pulse quotient respective pulse width measuring capacity must be used. The sign (+) indicates positive trigger pulse, TRIG+.
|
>= greater than; <= less than; ~= alternating current
A pin without further comments does not have a pin connection. (LP: LOGIC PROBE P= select pulse; p= visible pulses)
Pin nr
|
Lead colour
|
Component/function
|
In/out
|
Measuring condition
|
Measure between
|
Value
|
See
|
20
|
BU/RD
|
Parking heater/Auxiliary heater
|
Out
|
Activated
|
20-1
|
0 V
|
|
|
|
|
|
Not activated
|
20-1
|
B+
|
|