Dismantling


Important

The exhaust pipe's flexible section is highly sensitive to bending and must not be bent more than about 5°, as this could result in permanent deformation.

Do not allow the catalytic converter to hang from the flexible section.



1. Remove the heat shield over the exhaust manifold.

2. Disconnect the oxygen sensor's leads, undo the clip and cable clamps.

Important

Do not twist the leads. The oxygen sensor is sensitive to knocks and jolts and must be handled with care.


3. Unscrew the upper nuts at the joint between exhaust manifold and front exhaust pipe. Raise the car.

4. Remove the oxygen sensor.


5. Loosen the joint between the front exhaust pipe and the middle pipe.

6. Undo the remaining nuts at the joint between the front exhaust pipe and exhaust manifold.


7. Remove the two rubber mountings between the catalytic converter and subframe.

8. Lower the front exhaust pipe.


To fit


Important

The exhaust pipe's flexible section is highly sensitive to bending and must not be bent more than about 5°, as this could result in permanent deformation.

Do not allow the catalytic converter to hang from the flexible section.



1. Clean the joints.

2. Fit the rubber mountings between the catalytic converter and engine subframe. If necessary, change the rubber bushes.

3. Position the front exhaust pipe and secure it to the exhaust manifold by means of the two lower nuts.

Tightening torque: 40 Nm (30 lbf ft)

4. Bolt the front exhaust pipe and intermediate pipe together, using a new clamp.


Tightening torque: 30 Nm (22.5 lbf ft)

Important

To avoid leakage, joints should be tightened with new clamps.


Make sure that there is adequate clearance to parts next to the exhaust system.

Also make sure that the tailpipe from the rear silencer is positioned symmetrically in the opening cut out for it in the rear bumper.

5. Fit the oxygen sensor, but first lubricate the threads with Molycote 1000, part no. 30 20 971.

Tightening torque: 55 Nm (41 lbf ft)

Important

The oxygen sensor is sensitive to knocks and jolts and must be handled with care. It is important to ensure that the connection between oxygen sensor and union is gastight.


6. Lower the car to the floor.


7. Tighten the upper nuts on the joint between the exhaust manifold and front exhaust pipe.

8. Connect the oxygen sensor's leads and fit the clip and cable clamps.

9. Fit the heat shield over the exhaust manifold.