Trionic control module
Trionic control module |
Important | ||
If a winding in the APC valve is short-circuited, the control module is probably also damaged and any new valves being fitted will be destroyed. Consequently, in case of a short circuit, the valve and the control module must both be changed at the same time. |
||
1. |
Make sure the ignition is off.
|
2. |
Remove the glove box.
|
3. |
Fold back the carpet and remove the central locking system relay.
|
4. |
Unplug the connector and remove the control module.
|
To fit |
1. |
Fit the control module.
|
2. |
Plug in the connector.
|
3. |
Fit the central locking system relay.
|
4. |
Refit the glove box.
|
5. |
Reset the immobilizer in the following way:
|
• |
Connect Tech2 and turn the ignition key to ON
|
• |
Select Body and TWICE
|
• |
Select Immobilizing. The immobilizer will be programmed after about 10 seconds.
|