P0134
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Market US/CA: CHECK ENGINE
Misfiring can occur before trouble code is generated.
O2S Circuit. No Activity Detected. Sensor 1.
Fault symptoms
•
|
Market US/CA: CHECK ENGINE
|
•
|
Misfiring can occur before trouble code is generated.
|
On-Board Diagnostics
Type of diagnosis:
-
|
Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
|
Enable criteria:
-
|
Test 1:
Engine running. Main relay voltage above 10V. Preheating active for longer than 8 min.
|
-
|
Test 2:
Closed loop active.
|
Fault criteria:
-
|
Test 1:
Voltage has not been outside the range 0.400-0.600 V.
|
-
|
Test 2:
Closed loop active and voltage has not been outside the range 0.400-0.600 V for 10 s.
|
Dependents:
System reaction to a fault
:
-
|
Closed loop is blocked.
|
OK report:
-
|
Test 1 and Test 2 performed once and fault criteria not fulfilled. 60 s. has past and closed loop is still active. Fault criteria for P0131 or P0132 not fulfilled.
|
Fault handling:
(For more information, see
.)
Diagnostic help
Fault diagnosis concerns an electrical fault in connecting leads or in the sensor.
Functions in the diagnostic tool related to the fault:
•
|
Diagnostic status for the diagnosis.
|
•
|
Oxygen Sensor Value, unit V.
|
For information, see
.
Note
|
The oxygen sensor receives reference oxygen from the surrounding air via the connecting cables. For this reason, electrical contact spray or grease
must not
be used on the oxygen sensor connector.
|
Checking the wiring
Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.