Fan control, ACC
Fan control, ACC |
Removing |
1. |
Remove the glove box. See
Glove box
.
|
2. |
Remove the protective cover.
|
3. |
Remove both retaining bolts from the fan control.
|
4. |
Unplug the connector.
|
Fitting |
1. |
Plug in the connector.
|
2. |
Wipe old silicon paste off the evaporator's mounting surface.
Coat a thin layer of silicon paste, part No. 30 07 895, on the fan control's contact surface against the evaporator. This is important to ensure proper functioning and normal service life.
|
3. |
Fit the fan control in place, checking that its two sleeves enter the holes in the evaporator's mounting surface.
Screw the fan control in place. |
4. |
Refit the protective cover.
|
5. |
Put the glove box back in place. See
Glove box
.
|
6. |
Calibrate the ACC-system by simultaneously pressing the buttons “AUTO” and “OFF”.
|