Direct current motor, air recirculation flap
Direct current motor, air recirculation flap |
The air recirculation flap is operated by a DC motor. The flap has only two positions. When the motor has turned the flap to one of the end positions, the current passing through the motor winding is limited by two PTC resistors built into the motor. The ACC control module will also close the output after 10 seconds. PTC means Positive Thermal Coefficient and means that the resistance increases with increased heat (the opposite of NTC).
If the ignition has been turned off for more than 10 minutes, recirculation is selected 30 seconds after starting at the earliest, and only if the outside temperature is above 25°C and the required mixed-air temperature is the lowest possible (the cabin must be significantly cooled after starting).
Then, recirculation is selected in the following three cases:
• |
at an outside temperature above 37°C if the solar intensity exceeds 200 W/m
2
.
|
• |
at an outside temperature above 30°C if the requested mixed-air temperature is below 7°C and vehicle speed is below 5 km/h for an extended period (A/C system performance falls off)
|
• |
at an outside temperature above 20°C if the coolant temperature exceeds 118°C (the engine risks being overheated).
|
Recirculation can be selected manually on the panel. A symbol on the display indicates when the air is recirculated.
With the ignition turned off, fresh-air position is selected after 10 seconds.
Diagnosis |
In case of open circuit or short circuit, diagnostic trouble code B2410 is generated, and 21 is shown instead of right temperature at calibration.