SAAB WIS ONLINE

Resetting triggered limp-home solenoid

Resetting triggered limp-home solenoid


1. Remove the upper engine cover.


2. Put the ignition in ON position.


3. Contact Trionic with the diagnostic tool and clear diagnostic trouble codes.

4. Turn the ignition to OFF and wait for 10 seconds. Remove the cover over the throttle body.

5. Carefully push the end of the spring towards the throttle body.


6. Rotate the black tooth disc anti-clockwise with a screwdriver. A click will be heard in its end position.


7. Rotate the pedal arm clockwise.

8. Make sure the throttle arm does not follow with the pedal arm when it is rotated.

9. Fit the cover over the throttle body and the upper engine cover.