P0125
Symptom: CHECK ENGINE
P0125 |
Fault symptoms
• |
CHECK ENGINE
|
On-Board Diagnostics
Type of diagnosis:- |
Once per driving cycle. Interrupted when fault criteria fulfilled or OK reported. Restarts next driving cycle.
|
Enable criteria:
- |
Tests 1, 2 and 3:
Engine running. A counter accumulates a value for each second that passes since the engine was started. With the accelerator pedal depressed, the value is 1 and with the accelerator pedal released, the value is 0.5. Starting temperatures for intake air and coolant have been registered and the lowest of them has been selected.
|
Fault criteria:
- |
Test 1:
When the temperature value is below -7°C, the counter reaches 600 before closed loop starts.
|
- |
Test 2:
When the temperature value is between -7°C and 10°C, the counter reaches 300 before closed loop starts.
|
- |
Test 3:
When the temperature value exceeds 10°C, the counter reaches 120 before closed loop starts.
|
Dependents:
- |
P0115, P0119, P1131, P1132, P1133
|
System reaction to a fault:
- |
None.
|
OK report:
- |
Test 1: The number of adapted engine revolutions has at some time dropped. Test 2 performed once and fault criteria not fulfilled.
|
Fault handling: (For more information, see .)
- |
Type III.
|
Diagnostic help
Fault diagnosis concerns an electrical fault in connecting leads or in the sensor.Functions in the diagnostic tool related to the fault:
• |
Diagnostic status for the diagnosis.
|
• |
All readings in the group: LAMBDA STATUS.
|
• |
Oxygen Sensor Value, unit V.
|
• |
Coolant Temperature, unit °C.
|
For more information, see .