P0133
Read the instructions below then
start the fault diagnostic procedure.
Symptom: CHECK ENGINE.
O2S Circuit. Slow Response. Sensor 1.
Fault symptoms
On-Board Diagnostics
Type of diagnosis:
-
|
Once per driving cycle. Interrupted when fault criteria fulfilled or OK reported. Restarts next driving cycle.
|
Enable criteria:
-
|
General condition for this diagnostic trouble code: Atmospheric pressure must exceed 72 kPa as well as coolant and intake air temperature must exceed -7°C.
|
-
|
3 min since engine started. Engine speed 1300-2200 rpm. Load 250-500 mg/comb. Closed loop is active and stable. Air mass per combustion stable. Purge active. Coolant temperature above 70°C. When all the conditions are fulfilled, the number of combustions during 2 sensor transitions is counted.
|
Fault criteria:
-
|
Number of combustions exceeds 95.
|
Dependents:
-
|
P0115, P0116, P0117, P0118, P0119, P0131, P0132 and P0134.
|
System reaction to a fault:
OK report:
-
|
Diagnosis performed once and fault criteria not fulfilled.
|
Fault handling:
(For more information, see
Fault handling III, other emission-related components and functions
.)
Diagnostic help
Fault diagnosis concerns an internal fault in the sensor.
Functions in the diagnostic tool related to the fault:
•
|
Diagnostic status for the diagnosis.
|
For more information, see
Menu "Read Values"
.
Note
|
The oxygen sensor receives reference oxygen from the surrounding air via the connecting cables. For this reason, electrical contact spray or grease must
not