P1676
Read the instructions below then start the fault diagnostic procedure.
Symptom: Engine misfires or will not start.
P1676 |
Fault symptoms
• |
Engine misfires or will not start.
|
On-Board Diagnostics
Type of diagnosis:- |
Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
|
Enable criteria:
- |
Crankshaft rotating. Main relay voltage above 6V.
|
Fault criteria:
- |
Voltage on one of the outputs below 2V if the output is not active or exceeding 2V if the output is active. Fault criteria fulfilled after 2 s.
|
Dependents:
- |
None.
|
System reaction to a fault:
- |
Closed loop is blocked.
|
OK report:
- |
Enable criteria fulfilled and fault criteria not fulfilled within 60 s.
|
Fault handling: (For more information, see .)
- |
Type III. CHECK ENGINE does not go on.
|
Diagnostic help
Fault diagnosis concerns an electrical fault in connecting leads or in any of the injectors.Functions in the diagnostic tool related to the fault:
• |
Activate outputs for all injectors.
|
For more information, see .