P0753

Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK GEARBOX warning lamp on. TCM in limp-home mode.

P0753


Solenoid 1-2/3-4. Short to Ground.

Solenoid 1-2/3-4. Open Circuit / Short to B+.


Fault symptoms

CHECK GEARBOX warning lamp on.

TCM in limp-home mode.

Conditions

Shorting to ground.

Shorting or open circuit to B+.

Diagnostic help

The status of the 1-2/3-4 shift solenoid (S1) can be ascertained with the diagnostics instrument.

Select " Data Display / Output Control (New)" and " Solenoid 1-2/3-4 (S1)". Solenoid 1-2/3-4 (S1) should be activated (ON) for 1st and 3rd when driving, and deactivated (OFF) for the other gears.

The 1-2/3-4 shift solenoid (S1) can be activated with the diagnostics instrument.


- Select " Data Display / Output Control (New)" and “ Solenoid 1-2/3-4”