SAAB WIS ONLINE

Power supply

Power supply

Battery Voltage (+30 circuit)



+30 current is supplied via fuse 35 (22a) to the main instrument unit pin 1.

The control module uses current from the +30 circuit for its memory.



Battery Voltage (+15 circuit)

+15 current is supplied via fuse 17 (22a) to the main instrument unit pin 2.

The main instrument unit is activated by current from the +15 circuit.

Diagnostics

If there is no current supply from the +30 circuit, the trip meter will be zeroized every time the ignition is switched off.

If no +15 current is present, the main instrument unit will not be activated. The engine will not start, as bus communication has not been activated.

The function has no diagnostics.