Menu: "Activate"
Menu: "Activate" |
Important | ||
The activate function must always be used with caution. Always deactivate an activated function before moving on to a new Tech 2 menu item. Also remember to clear any DTCs in the ABS or other systems when you've finished the work. |
||
Note
Note | ||
When a system function is activated by the diagnostic instrument, the control module is being instructed to execute a command that it would not normally be doing. In the Activate mode, the diagnostic tool tests the control module and you should therefore use the Activate command with caution. An activated function is always reset when you leave the Activate mode to move to another menu item. |
Activate | Description | Value |
ABS lamp
|
Switches ABS warning lamp on and off.
|
ON/OFF
|
Pump motor
|
Switches pump motor on and off.
|
ON/OFF
|
Front Left Inlet Valve
|
Valve activated for 30 s at 1 Hz
|
ON/OFF
|
Front Left Outlet Valve
|
Valve activated for 30 s at 1 Hz
|
ON/OFF
|
Front Right Inlet Valve
|
Valve activated for 30 s at 1 Hz
|
ON/OFF
|
Front Right Outlet Valve
|
Valve activated for 30 s at 1 Hz
|
ON/OFF
|
Rear Left Inlet Valve
|
Valve activated for 30 s at 1 Hz
|
ON/OFF
|
Rear Left Outlet Valve
|
Valve activated for 30 s at 1 Hz
|
ON/OFF
|
Rear Right Inlet Valve
|
Valve activated for 30 s at 1 Hz
|
ON/OFF
|
Rear Right Outlet Valve
|
Valve activated for 30 s at 1 Hz
|
ON/OFF
|
Valve Test - Front Left
|
See
Valve test
|
|
Valve Test - Front Right
|
|
|
Valve Test - Rear
|
|
|
Valve Test - Rear Left
|
|
|
Valve Test - Rear Right
|
|