Calibration
Calibration |
Calibration is done by simultaneously pressing the AUTO and OFF buttons, and it takes about 30 seconds. Calibration must be performed if the battery has been removed/discharged, if the ACC unit or a stepping motor has been replaced, or its position has been altered. As the calibration is being done, the ACC runs through a self-check.
Calibration is done automatically directly following ignition turn-on in the following cases:
• |
New ACC is installed.
|
• |
+30 interrupted earlier than 10 minutes from the last time ignition was turned off (common in connection with battery replacement, for example).
|
Diagnosis |
During calibration, a number of stored diagnostic trouble codes are shown on the display instead of the temperature. The codes numbered from 0-23 are shown for 3 seconds each. The number of diagnostic trouble codes is displayed using the fan bars. A maximum of six trouble codes can be stored at any time.