Fifth bow latch
Fifth bow latch |
Removing |
1. |
Raise the soft top cover and remove the covering shell.
|
2. |
Connect the diagnostics tool and run the fifth bow latch motor using the command:
“STC” “Activate” “5th bow latch motor ” “Lock” |
3. |
Remove the clips and remove the operating arm from the fifth bow latch.
|
4. |
Remove the cable ties and unplug the electric connection.
|
5. |
Remove the bolts that secure the latch and leave the access flap suspended by the cable.
|
Fitting |
1. |
Fit the latch and push the hook into the reinforcement bracket. Tighten the lower bolt.
|
2. |
Fit the access flap striker plate. Make sure that the guide ends up in the latch groove. Tighten the upper and lower bolt.
|
3. |
Plug in the connectors and fit cable ties.
|
4. |
Fit the operating arm to the latch and press on the clip.
|
5. |
Connect the diagnostics tool and erase any diagnostic trouble code.
|
6. |
Refit the shell.
|