Combustion chamber, auxiliary heater
Combustion chamber, auxiliary heater |
1. |
Remove the heater, see
![]() ![]() |
2. |
Remove the cover over the blower fan.
|
3. |
Loosen the four bolts on the control module, remove the cover with the air intake and carefully bend out the control module.
|
4. |
Remove the connector and remove the control module from the heater.
![]() |
5. |
Remove the blower fan. Remove the gasket.
![]() |
6. |
Lift out the combustion chamber. Remove the gasket.
![]() |
To fit |

1. |
Check to make sure that the heat exchanger O-ring is undamaged and that there are no leaks. Replace if needed.
|
2. |
Clean the sealing surfaces. Change gasket and fit the combustion chamber, only fits one way.
|
3. |
Replace the gasket and fit the blower fan. Fit the gasket with the three holes.
![]() |
4. |
Fit connector B2 to the control module.
![]() |
5. |
Fit the cover with air intake and control module.
![]() |
6. |
Fit the cover.
|
7. |
Fit the heater, see
![]() ![]() |