P1652
Read the instructions below then start the fault diagnostic procedure.
Symptom: CHECK ENGINE lamp on.
P1652 |
Fault symptoms
• |
CHECK ENGINE lamp on.
|
Conditions
The following conditions apply for this DTC:• |
The main relay is closed too late. The main relay circuit is checked during afterrun. When the control module stops grounding pin K28 to the main relay, a clock is started. If it takes longer than 3 seconds for the power to disappear from pin 5 after grounding stops on pin K28 three times in a row, a DTC will be generated the next time the ignition is on.
|
Diagnostic help
PSG 16 controls whether the main relay is closed within the desired time. Check that the main relay works.The DTC can also be caused by a short-circuit to ground on the relay coil's ground lead or a short-circuit to B+ in the main relay circuit.