B1350

Read the instructions below then start the fault diagnostic procedure.

Symptom: Experienced temperature in cabin is too high or low when compared to set temperature.

B1350


Cabin temperature sensor. Shorted to ground

Cabin temperature sensor. Open circuit/shorted to B+.


Fault symptom

Experienced temperature in cabin is too high or low when compared to set temperature.

Conditions

The following conditions apply:


• Open circuit or short-circuit to B+ on pin 20 >4.9 V.

• Shorted to ground on pin 20 <0.1 V.

• Measured every 440 ms and 5 measurements in a row are required to generate a diagnostic trouble code.

• The diagnostic trouble code is erased after ignition has been switched on 20 times if the problem conditions have not been fulfilled.

• When the diagnostic trouble code is generated, a replacement value is used. The replacement value used at ignition turn-on is the outside temperature and then the calculated temperature at head level for the front-seat passenger and driver.