SAAB WIS ONLINE

Valve housing

Valve housing

To remove

Important

Automatic transmission up to and including 02GV 706486 : The wiring harness must also be changed when changing the valve housing so it suits the new one.



1. Remove the Valve housing cover.

2. Detach the solenoid electrical connections and the temperature sensor.


3. Undo the marked bolts with 10 mm heads which secure the valve housing.

Note

Start with the two bolts furthest down to the left which secure the cover to the oil ducts and save the two top retaining bolts until last. The bolts have different lengths.


Important

The ducts are filled with oil.


4. Carefully detach the manual valve from the selector lever out of the attachment lug and carefully remove the valve housing downward.

Note

Make sure that the two O-rings located inside the valve housing do not fall away.


5. Replace the O-rings if necessary


To fit

Important

Automatic transmission up to and including 02GV 706486 : The wiring harness must also be changed when changing the valve housing so it suits the new one.



1. Fit the O-rings. Fit the valve housing in position.

Note

Carefully guide the selector lever arm into position and fit the valve housing on the gearbox.



2. Fit the valve housing.

Tightening torque 7 Nm (5 lbf ft)

Note

The bolts have different lengths.


3. Connect the solenoid electrical cables and fit the temperature sensor.

4. Fit the Valve housing cover .