Left mixed air stepping motor
Left mixed air stepping motor |
To remove |
1. |
Dismantle the
driver's acoustic insulation
.
The left mixed air stepping motor is on the lower part of the heating and ventilation unit's left side. |
2. |
Dismantle the stepping motor's link arm from the heating and ventilation unit's link arm.
|
3. |
Remove the screws from the stepping motor.
|
4. |
Dismantle the stepping motor and its connector. The stepping motor's connector is dismantled by pressing in the lock and pulling out the connector.
|
To fit |
1. |
Fit the stepping motor and its connector. Make sure the connector locks correctly.
|
2. |
Fit the stepping motor's link arm to the heating and ventilation unit's link arm.
|
3. |
Fit the
driver's acoustic insulation
.
|