SAAB WIS ONLINE

ACC / B0166 05

Read the instructions below then start the fault diagnostic procedure.

  B0166 05


Indoor Temperature Sensor. Open Circuit / Short to B+



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Voltage on control module sensor input exceeds 4.8 V.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

In case of a fault, the control module will use the mixed air temperature.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Compartment Temperature Sensor
(See also description of readings/activations in diagnostic tool)