ACC / B0175 02
Read the instructions below then 
start the fault diagnostic procedure.
	
Air Mix Temperature Sensor Left Vent Circuit,  Short to Ground

On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
| Voltage on control module sensor input is below 0.2 V. | 
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
In case of a fault, the control module will use the value from the mixed air temperature sensor, left-hand floor.
Diagnostic help
Diagnosis regards:
| Electrical fault in connecting leads or component. | 
Functions in the diagnostic tool related to the fault:
| Air Mix Temperature Sensor Left Vent | 
| Air Mix Temperature Left Vent | 
| Air Mix Temperature Sensor Left Floor | 
| Air Mix Temperature Left Floor | 
| (See also description of readings/activations in diagnostic tool) |