ACC / B0261 01
Read the instructions below then start the fault diagnostic procedure.
B0261 01 |
On-board diagnosis
Type of diagnosis:
Continuous |
Enable criteria:
Ignition ON. |
Fault criteria:
Short-circuit to B+ or high current consumption in the circuit of the air distribution damper motor. |
System reaction to a fault:
None |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
Vent Door Motor Left |