Evaporator Temperature Sensor Circuit, Short to Ground

On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
| Voltage on control module sensor input is below 0.2 V. | 
System reaction to a fault:
| The control module uses outside temperature as a substitute value. | 
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
| Electrical fault in connecting leads or component. | 
Functions in the diagnostic tool related to the fault:
| Evaporator Temperature Sensor |