ACC / B0522 05
Read the instructions below then 
start the fault diagnostic procedure.
	
Evaporator Temperature Sensor Circuit, Open/Short to B+

On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
| Voltage on control module sensor input exceeds 4.8 V. | 
System reaction to a fault:
| The control module uses outside temperature as a substitute value. | 
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
| Electrical fault in connecting leads or component. | 
Functions in the diagnostic tool related to the fault:
| Evaporator Temperature Sensor |