BCM / B0473 06
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: Faulty cabin fan function when parking heater activated.
	
Parking Heater Fan Relay Circuit, Open/Short to Ground

Fault symptom
Faulty cabin fan function when parking heater activated.
On-board diagnosis
Type of diagnosis:
Enable criteria:
| Parking heater fan relay activated. | 
Fault criteria:
| When the current on the output is 0A. | 
System reaction to a fault:
| Control module output turned off for 2 seconds. | 
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
| Electrical fault in connecting leads or component. | 
Functions in the diagnostic tool related to the fault:
| Parking Heater Fan Relay (MCC) | 
| (See also description of readings/activations in diagnostic tool) |