CIM / U2100 00

Read the instructions below then start the fault diagnostic procedure.

  U2100 00


CIM was Missing on P-Bus



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.
Voltage is over 9V but under 16V

Fault criteria:

Control module absent on the P-bus.

System reaction to a fault:

None

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

If the DTC is stored and read with the diagnostic instrument, it indicates intermittent bus lead fault.

Diagnostic help

Diagnosis regards:

Electrical fault on bus leads or in the component.

Functions in the diagnostic tool related to the fault:

Test value:
Bus Off Counter, P-Bus
Response Test
Read / Reset Bus Configuration
(See also description of readings/activations in diagnostic tool)